(021) 7321129, 7323285   267543E9   081385262121                          
               This email address is being protected from spambots. You need JavaScript enabled to view it.      

 

 
Small in size extremely accurate and easy to use Infrared Thermometer. IP54 rated for dust and water resistance.
 
Produk terlaris dari Kyoritsu. Segera dapatkan dengan harga special

Gratis ongkos kirim untuk wilayah Jakarta

 

Infrared Thermometer Fluke 568

Infrared Thermometer Fluke 568
  Hubungi Kami

 

Two-in-one IR and contact thermometers with an innovative dot matrix display.

With a simple, 3-button on-screen menu interface (in 6 languages) the Fluke 568 and 566 digital laser thermometers make even complex measurements easy. Quickly navigate advanced features to adjust emissivity, start data logging, or turn on and off alarms - with just a few pushes of a button.

With a rugged, easy-to-use, ergonomic design, the Fluke 568 and 566 two-in-one contact and non contact thermometers can stand up to tough industrial, electrical, and mechanical environments. These tools go beyond other IR thermometers (or pyrometers), helping you work more efficiently in more applications.

 

Product specifications
Infrared temperature range
566:  -40 °C to 650 °C (-40 °F to 1202 °F)
568:  -40 °C to 800 °C (-40 °F to 1472 °F)
Infrared accuracy
   < 0 °C (32 °F): ± (1.0 °C (± 2.0 °F) + 0.1°/1 °C or °F);
> 0 °C (32 °F): ± 1 % or ± 1.0 °C (± 2.0 °F), whichever is greater
Display resolution
   0.1 °C / 0.1 °F
Infrared spectral response
   8 µm to 14 µm
Infrared response time
   < 500 msec
Thermocouple Type-K input temperature range
   -270 °C to 1372 °C (-454 °F to 2501 °F)
Thermocouple Type-K input accuracy
-270°C to -40°C:  ± (1 °C + 0.2 °/1 °C) (-454 °F to -40 °F: ± (2 °F + 0.2 °/1 °F))
-40°C to 1372°C:  ± 1 % or 1 °C (-40 °F to 2501 °F: ± 1 % or 2 °F), whichever is greater
D:S (distance to measurement spot size)
566:  30:1
568:  50:1
Laser sighting
   Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size
   19 mm (0.75 in)
Emissivity adjustment
   By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with Date/Time stamp
566:  20 points
568:  99 points
PC Interface and cable
566:  None
568:  USB 2.0 with FlukeView® Forms software
Hi/Low alarms
   Audible and two-color visual
Min/Max/Avg/Dif
   Yes
Display
   Dot matrix 98 x 96 pixels with function menus
Backlight
   Two levels, normal and extra bright for darker environments
Trigger lock
   Yes
Switchable Celsius and Fahrenheit
   Yes
Power
566:  2 AA/LR6 Batteries
568:  2 AA/LR6 Batteries and USB when used with a PC
Battery life
If used continuously:  laser and backlight on,12 hours; laser and backlight off, 100 hours
Operating temperature
   0 °C to 50 °C (32 °F to 122 °F)
Storage temperature
   -20 °C to 60 °C (-40 °F to 140 °F)
Bead thermocouple Type-K range
   -40 °C to 260 °C (-40 °F to 500 °F)
Bead thermocouple Type-K accuracy
   ± 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F), typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F)
 

Buana Survey
- Tentang Kami
- Hubungi Kami

 
 
 
 
  
 
  
 

 








Jalan. Muchtar Raya No.1D Kreo Utara, Larangan Utara Kode Pos 15156

Telp. 021 - 7321129, 021 - 7323285

 Fax. 021-7302811

GPS - SURVEY INSTRUMENT
TEST & MEASUREMENT
GEOLOGICAL TOOLS - SCOPE
RADIO COMMUNICATION - LASER LEVEL






 
 
 

 
Friday the 22nd. Copyright @ 2013 BuanaSurvey | Home | Joomla 3 Templates Joomlaskins